FM Transmitter Measurement Report
Created: 2025-05-07 02-27-11
Measuring equipment: P75/P175/P275 |
http://pira.cz |
Station Details
Frequency |
Signal
Reception |
Station
Name |
106.40 MHz |
5/5, 26 dBuV |
R-CB |
Pilot |
RDS |
Phase
Difference |
6.6 kHz |
2.6 kHz |
83 deg |
|
Frequency Deviation
Limit |
Measuring
Tolerance |
75,0 kHz |
2,0 kHz |
MIN
Hold |
Max. Samples at |
Total
Samples |
% above 77,0
kHz |
17 kHz |
42 kHz |
7913 |
0,0000 |
|
Modulation Power
Limit |
Measuring
Tolerance |
0,0 dBr |
0,2 dBr |
MIN |
AVE |
MAX |
% above
0,2 dBr |
-1,4 dBr |
-0,90 dBr |
-0,5 dBr |
0,0 |
|
Radio Data System
PS |
PI |
PTY |
TP |
TA |
MS |
DI |
CT |
"R-CB " |
250D |
9 (Varied) |
1 |
0 |
0 |
0 |
2:27, 7.05.2025 |
RT |
"Zpravy z regionu - rozhovory - dobre rady - souteze " |
AF |
EON |
88.2, 103.9, 106.4 MHz |
- |
|
|